چکیده: 

This paper presents the application of automatic under voltage load tripping and switching of shunt reactors as counter measures for fault induced delayed voltage recovery (FIDVR). As dynamic behavior of loads has significant impact on simulating FIDVR, proper load modeling is also discussed in this paper. Simulations conducted on actual network show that the proposed load model is effectively able to simulate FIDVR. It also shown that automatic under voltage load shedding and switching of shunt reactors can be used as counter measures for reducing risk of voltage collapse or over voltage conditions that may take place following load tripping caused by FIDVR.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 238

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسنده: 

SOLEIMANI HAMIDEH | Azizi Tousi Ali

اطلاعات دوره: 
  • سال: 

    2013
  • دوره: 

    28
تعامل: 
  • بازدید: 

    155
  • دانلود: 

    0
چکیده: 

GENERATED POWER OF PHOTOVOLTAIC HAS LOW RELIABILITY. SO, TO HELP IMPROVE THE RELIABILITY CAN BE USED AUXILIARY SOURCE WHICH THIS SYSTEM IS CALLED HYBRID SYSTEM. THIS PAPER PRESENTS THE HYBRID SYSTEM INCLUDING PHOTOVOLTAIC AND BATTERY THAT SUPPLY A DC LOAD. CONTROL OF THE SYSTEM HAS TWO MAIN OBJECTIVES ARE MAXIMUM POWER POINT TRACKING AND FIXING DC Bus voltage AT CONSTANT VALUE TO OBTAIN OBJECTIVES RESPECTIVELY, A BOOST AND A BIDIRECTIONAL BUCK-BOOST DC-DC CONVERTER ARE USED. THE PERTURBATION AND OBSERVATION METHOD IS USED FOR MAXIMUM POWER POINT TRACKING. ALSO, HYSTERESIS METHOD IS USED FOR CONTROL OF CONVERTERS WHICH ARE LOCATED BETWEEN PHOTOVOLTAIC, BATTERY AND DC Bus. HIGH SPEED RESPONSE AND SIMPLICITY ARE ADVANTAGES OF HYSTERESIS METHOD. SO INDUCTOR AND CAPACITOR VALUES IN THE SYSTEM TO BE SELECTED LARGE ENOUGH. THE SYSTEM SIMULATED IN MATLAB/SIMULINK SOFTWARE. SIMULATION RESULTS HAVE SHOWN THAT THE SYSTEM WILL BE OPERATED CORRECTLY AT DIFFERENT MODES.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 155

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0
نشریه: 

کنترل

اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    15
  • شماره: 

    4
  • صفحات: 

    39-47
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    53
  • دانلود: 

    14
چکیده: 

جداسازی توان سمت شبکه از توان ورودی یکی از مهمترین چالش های سیستم های تکفاز متصل به منابع تجدیدپذیر است. هدف اصلی در این سیستم ها کاهش ظرفیت خازن جداساز می باشد. اما کاهش ظرفیت خازن مشکلاتی از قبیل افزایش اعوجاج هارمونیکی کل جریان شبکه و همچنین نوسانات (فراجهش و فروجهش) ولتاژ خازن جداساز را ایجاد می کند. لذا استفاده از روش های کنترلی جهت بهینه سازی عملکرد این سیستم ها ضروری خواهد بود. کنترل کننده ولتاژ وظیفه دارد ولتاژ خازن باس را تنظیم کرده، هارمونیک دوم شبکه را حذف و بده بستانی میان هزینه سیستم با دو پارامتر اعوجاج هارمونیکی کل و فراجهش برقرار نماید. در این مقاله یک فیلتر ناچ با رویکرد دیجیتال ارائه شده است که توانسته سرعت پاسخ گذرای سیستم را افزایش دهد و همچنین ریپل هارمونیکی را به خوبی از بین ببرد. روابط مربوط به ظرفیت خازن با اعوجاج هارمونیکی کل و فراجهش بطور کامل فراهم شده است. همچنین روابط ریاضی مربوط به طراحی فیلتر ناچ دیجیتال نیز آورده شده است. تمامی شبیه سازی ها در محیط سیمولینک متلب انجام شده است. سیستم مورد بررسی یک پنل خورشیدی 250 وات متصل به شبکه 220 ولت موثر 50 هرتز می باشد. میزان اعوجاج هارمونیکی کل جریان تزریقی به شبکه حدودا برابر 0/6 درصد بدست آمده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 53

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 14 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1399
  • دوره: 

    50
  • شماره: 

    2 (پیاپی 92)
  • صفحات: 

    889-898
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    380
  • دانلود: 

    100
چکیده: 

در سال های اخیر به علت گسترش تجهیزات غیرخطی نظیر ادوات الکترونیک قدرت، کوره های قوس الکتریکی و. . . شبکه های برق دچار آلودگی هارمونیکی شده اند. در این مقاله روشی جدید برای شناسایی و تعیین سهم هر یک از فیدرهای متصل به یک باس در آلودگی هارمونیکی ولتاژ باس در شبکه های شعاعی، ارایه می شود. در هر شبکه ای که ساختاری شعاعی داشته باشد، با استفاده از این روش می توان در باس هایی که دچار اعوجاج هارمونیکی در ولتاژ شده اند، اولا فیدرهای مقصر (فیدرهایی که منشا این اعوجاج هارمونیکی بوده اند) را از بین همه ی فیدرهای متصل به آن، شناسایی کرد؛ ثانیا سهم هارمونیکی (میزان مقصر بودن) هر یک از فیدرها را به صورت کمی تعیین کرد. در این روش سهم هارمونیکی هر یک از فیدرهای متصل به یک باس (از یک شبکه ی شعاعی)، در اعوجاج هارمونیکی ولتاژ آن باس، برای هر یک از مراتب هارمونیکی، به صورت مجزا تعیین می شود؛ علاوه بر آن، سهم هارمونیکی هر یک از این فیدرها، در اعوجاج هارمونیکی کل ولتاژ آن باس نیز تعیین می شود. این روش مبتنی بر مقایسه ی هر یک از فیدرها با فیدر خطی متناظر با آن ها هست. در این مقاله روش جدیدی برای مدل سازی هارمونیکی هر یک از فیدرهای متصل به یک باس (از یک شبکه ی شعاعی) نیز ارایه می شود، که مبتنی بر رگرسیون خطی بین نمونه های ولتاژ و جریان و کمینه سازی مجموع مربعات خطا هست.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 380

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 100 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    17
  • شماره: 

    2
  • صفحات: 

    125-131
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    515
  • دانلود: 

    143
چکیده: 

مبدل پل H متوالی یکی از پرکاربردترین مبدل های چندسطحی در مبدل های توان بالا است. اما نامتعادلی ولتاژ DC خازن ها در این مبدل از مشکلات به کارگیری آنها به خصوص در کاربردهایی است که خازن ها از طریق شبکه شارژ می شوند. علت عمده بروز این نامتعادلی در ولتاژ خازن ها، تفاوت در تلفات هر سلول مبدل است. در این مقاله روش جدیدی برای متعادل سازی ولتاژ خازن باس DC مبدل چندسلولی پل H متوالی ارائه می شود که نیاز به اندازه گیری جریان عبوری از سلول ها ندارد. روش پیشنهادی که انتقال فاز حامل تطبیقی (ACPS) نامیده می شود بر پایه استفاده از روش مدولاسیون عرض پالس مبتنی بر انتقال فاز بنا شده که با اندازه گیری ولتاژهای باس DC و تغییر مقدار انتقال فاز سلول ها به متعادل سازی ولتاژ خازن ها می پردازد. روش پیشنهادی به صورت ریاضی تحلیل شده و جهت متعادل سازی ولتاژ خازن ها بر روی یک مبدل پل H متوالی هفت سطحی در کاربرد مبدل به عنوان جبران ساز سنکرون استاتیکی (STATCOM) استفاده شده است. شبیه سازی های متعددی در نرم افزار MATLAB/Simulink انجام شده که به خوبی کارایی روش متعادل سازی پیشنهادی در حفظ تعادل ولتاژ باس DC سلول ها را نشان می دهد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 515

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 143 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1402
  • دوره: 

    53
  • شماره: 

    1
  • صفحات: 

    69-79
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    202
  • دانلود: 

    43
کلیدواژه: 
چکیده: 

In this paper, a novel risk-based, two-objective (technical and economical) optimal reactive power dispatch method in a wind-integrated power system is proposed which is more consistent with operational criteria.  The technical objective includes the minimization of the new voltage instability risk index. The economical objective includes cost minimization of reactive power generation and active power loss. The proposed voltage instability risk employs a hybrid possibilistic (Delphi-Fuzzy)-probabilistic approach that takes into consideration the operator’s experience, the wind speed and demand forecast uncertainties when quantifying the risk index. The decision variables are the reactive power resources of the system. To solve the problem, the modified multi-objective particle swarm optimization algorithm with sine and cosine acceleration coefficients is utilized. The method is implemented on the modified IEEE 30-Bus system. The proposed method is compared with those in the previously published literature, and the results confirm that the proposed risk index is better at estimating the voltage instability risk of the system, especially in cases with severe impact and low probability. In addition, according to the simulation results compared to typical security-based planning, the proposed risk-based planning may increase the security and economy of the system due to better utilization of system resources.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 202

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 43 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نشریه: 

دریافنون

اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    6
  • شماره: 

    1 (پیاپی 15)
  • صفحات: 

    1-15
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    446
  • دانلود: 

    183
چکیده: 

امروزه در برخی کاربردها به ویژه برای نیروگاه های خانگی طراحی سیستم های فتوولتاییک تک فاز متصل به شبکه به سمت استفاده از میکرواینورترها با محدوده توان 150W تا 300W متمایل شده است. هم چنین در صنایع دریایی می توان از میکرواینورترهای فتوولتاییک به منظور تولید بخشی از انرژی الکتریکی مورد نیاز در کشتی ها استفاده کرد. در میکرواینورترهای تک فاز ضربان با فرکانس دوبرابر فرکانس شبکه روی ولتاژ باس DC وجود دارد که باعث ایجاد هارمونیک در جریان خروجی و کاهش ضریب توان می شود. برای کاهش این ضربان اغلب از خازن های الکترولیتی با ظرفیت زیاد در باس DC استفاده می شود که عیب آن کم بودن طول عمر این خازن هاست. برای برطرف کردن این مشکل لازم است خازن های الکترولیتی با خازن های فیلم نازک که طول عمر زیاد و ظرفیت کمی دارند جایگزین شوند. با کاهش ظرفیت خازن دامنه ضربان ولتاژ باس افزایش می یابد و با استفاده از کنترل کننده متداول باس (PI) بده بستان بین THD جریان خروجی و نوسانات (فراجهش و فروجهش) ولتاژ باس غیرقابل حل است. در این مقاله با به کار بردن روش های کنترلی پیشنهاد شده میکرواینورتری طراحی و شبیه سازی شده است که در آن بدون استفاده از عناصر اضافه این بده بستان حل شده است. این میکرواینورتر به شبکه 220V و 50Hz متصل است، در باس آن از خازن با ظرفیت بسیار کم 20µ F استفاده شده، در پاسخ به پله 200W توان ورودی، ولتاژ باس آن فراجهش و فروجهش ناچیزی داشته و THD جریان تزریقی آن به شبکه در توان 250W برابر %0. 44 است. درستی روش پیشنهادی با شبیه سازی در محیط سیمولینک متلب تحقیق شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 446

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 183 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    8
  • شماره: 

    4 (ویژه نامه پرتوهای یون ساز)
  • صفحات: 

    261-266
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    745
  • دانلود: 

    233
چکیده: 

هدف از مطالعه حاضر، بررسی اثر نوسانات ولتاژ حاصل از دستگاه های تولید کننده اشعه ایکس بر کیفیت پرتوهای اشعه ایکس می باشد. برای رسیدن به این موضوع باید ابندا طیف انرژی حاصل از تیوب های تولید کننده اشعه ایکس در محدوده رادیوگرافی تشخیصی شبیه سازی شده و با نتایج تجربی اندازه گیری شده، صحت سنجی شود. آنالیز آماری انجام گرفته روی نتایج نشان می دهد که تفاوت معنی داری بین نتایج شبیه سازی و نتایج تجربی وجود ندارد. سپس تاثیر ریپل ولتاژ روی طیف انرژی شبیه سازی و بررسی شد. برای بررسی اثر نوسانات ولتاژ بر میزان کیفیت پرتو محاسبات لایه نیم جذب (HVL) انجام گرفت. نتایج حاصل از این تحقیق نشان داد که نوسانات ولتاژ می تواند تا حدود 56% مقدار HVL را در ولتاژ kV100 و در حدود 75% در ولتاژ kV80 کاهش دهد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 745

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 233 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1396
  • دوره: 

    14
  • شماره: 

    4
  • صفحات: 

    262-270
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1550
  • دانلود: 

    324
چکیده: 

بارزدایی، آخرین واکنش برای کنترل و پایداری سیستم قدرت در هنگام وقوع اغتشاش است. تعیین محل و مقدار بارزدایی از مسایلی است که همواره گریبان گیر بهره برداران سیستم قدرت بوده است. در این مقاله روش جدیدی برای تعیین باس مناسب جهت انجام بارزدایی ولتاژی پیشنهاد می شود. در روش پیشنهادشده بر خلاف روش های پیشین از دو شاخص حساسیت ولتاژ نسبت به توان اکتیو و توان راکتیو بارها استفاده می شود تا باس مناسب جهت بارزدایی ولتاژی مشخص شود. در نظر گرفتن توان راکتیو بارها در فرایند تعیین باس مناسب برای بارزدایی ولتاژی باعث قطع توان راکتیو بیشتر در پله های ابتدایی بارزدایی ولتاژی شده و پروفیل ولتاژ بهبود می یابد. در نتیجه، توان اکتیو کمتری توسط بارزدایی ولتاژی قطع می شود. روش پیشنهادی به همراه روش مبتنی بر حساسیت ولتاژ نسبت به توان اکتیو در شبکه تست 118باسه IEEE و شبکه 39باسه New England پیاده سازی می شوند تا درستی روش پیشنهادشده مورد بررسی قرار گیرد. نتایج حاصل نشان دهنده برتری روش پیشنهادی نسبت به روش حساسیت ولتاژ نسبت به توان اکتیو است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1550

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 324 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 3
نویسندگان: 

SADRI G.H.

اطلاعات دوره: 
  • سال: 

    2002
  • دوره: 

    27
  • شماره: 

    1
  • صفحات: 

    39-41
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    466
  • دانلود: 

    0
چکیده: 

Bus accident is a major health problem for Bus drivers. To identify the risk factors involved in Bus accidents and to design a model showing the relation between the risk factors and Bus driver’s health status, 219 Bus drivers who worked for travel agencies in two areas of west and central Iran were enrolled into this study. We used a questionnaire to gather information regarding both the Bus drivers’ health status and Bus accident. The most prevalent health problems among Bus drivers were musculoskeletal disorders, ulcer, hyperacidity, obesity, hypertension and diabetes. There was a significant (p<0.05) correlation between the chance of Bus accidents and occurrence of low back pain, leg pain, neck pain, hypertension and migraine. Based on the results of this study we suggest a model that can be used to design a prevention plan in making Bus transportation safer. In light of this study, more comprehensive studies can be planned for the safety of traveling by Bus, in Iran. Bus driver’s health status is a determinant factor in the incidence of accidents.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 466

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button